Types of Fire Pumps at Kelair

Kelair Containerised Fire Protection Pumpsets

As specialist Australian pump suppliers since 1975, Kelair Pumps Australia’s fire pumpsets are favoured by major mining companies including Rio Tinto, BHP, FMG and Glencore and are installed in mining operations across the country.

  • Diesel & Electric Hydrant Booster Pumps.
  • Fire Hose Reel & Jacking Pumps.
  • Kelair produces a range of fire hose reel and jacking pumpsets electrically driven and set for automatic start/stop.
  • Fire Sprinkler Pumpsets.
  • A complete range of fire sprinkler pumpsets for all applications, fully compliant to technical specifications.

Kelair Deisel And Electric Hydrant Booster Pumps

Kelair offers fully compliant AS2941, fully-packaged hydrant booster pumps complete will fully-valved suction and discharge manifolds and by-pass line. Packaged systems provide simple installation. All units are factory tested prior to delivery and are backed by Kelair’s field service technicians.

  • Annubar test lines.
  • Pressure-sustaining / relief valves.
  • Onsite Commissioning.
  • On Site Flow Tests.
  • Automatic and manual jacking pumps.

Kelair Fire Hose Reel And Jacking Pumps

These units boost water to fire hose reels as and when it is needed. Built to AS 2941 they are supplied as a complete package.

  • Compliance with AS2941 available.

Options:

  • Weatherproof units.
  • Flow switch control.
  • Integrated by-pass pipework and valves.
  • Inching button.

Kelair: Fire Sprinkler Pumpsets

A complete range of fire sprinkler pumpsets for all applications, fully compliant to technical specifications

A complete range of fire sprinkler pumpsets for applications such as high-rise buildings, low-rise buildings, hospitals, mine sites, industrial factories and processing plants.

Units can be supplied to comply with the following standards:

  • AS2941
  • AS/ISO 9906-2018

Design and Installation

Designing and installing a fire pump system is a critical aspect of fire protection in buildings and industrial facilities. It involves careful planning, adherence to codes and standards. Below are the key steps involved in the design and installation of a fire pump system:

  • The type of building and occupancy.
  • The hazard class of the building.
  • The available water supply.
  • The required pump capacity and pressure.

Remember that the design and installation of a fire pump system should be carried out by qualified professionals with experience in fire protection engineering and compliance with local regulations.

Australian Regulations and Standards

Fire pumps in Australia must comply with several regulations and standards, including:

•AS 2941-2013: Fixed Fire Protection Installations – Pumpset Systems

AS 2118.1-2017: Automatic Fire Sprinkler Systems

National Construction Code (NCC)

Maintenance and Testing

Proper maintenance of fire pumps is crucial to ensure their reliability and effectiveness in the event of a fire emergency. Fire pump maintenance should be carried out in accordance with manufacturer recommendations, industry standards as per AS 1851Regular maintenance and testing as per AS 1851, are essential to ensure that fire pumps are functioning correctly and are ready for use in case of an emergency.

Tips to Maintain Your Fire Pump

  • Perform weekly pump runs.
  • Check the power source of your fire pump.
  • Ensure your Fire Alarm Panel is receiving signals.

1. Prevent parts inside the fire pump from locking in place by lubricating them and moving them around.

2. Check the components inside your fire pump such as the pressure relief valve, the packing, and casing relief valve. Also, make sure that everything is opening and closing properly.

3. Monitor your water pressure gauge. If the pressure is above or below the normal reading, make sure to contact your fire protection professional.

Why Choose Fire Pumps From us?

Kelair has a range of fire pumps that have delivered on quality and durability over the years.

  • High Performance
  • Reliability
  • Custom Build
  • Easy to Use
  • Value for your money

How our experts at Kelair can help you:

  • Design and cost a system or project.
  • Customise and engineer solutions for your specific application.
  • Provide spare parts and maintenance services.
  • Pump Manuals and Technical Guides

Conclusion

Fire pumps are an imperative component of any fire protection system and ensuring that they are compliant with Australian regulations and standards is essential for the safety of occupants and property. By understanding the different types of fire pumps, the applicatory regulations, and the constituents influencing their selection and installation, building owners and managers can ensure that their fire pump systems are up to date and ready for use in case of an emergency.

For More Information

Sign up for the latest news

Local call Australia-wide 1300 789 466

Branches

Kelair Pumps Australia

VIC

228 Atlantic Dr
Keysborough VIC 3173

TAS

Unit 1, 12 South St
Invermay TAS 7248

QLD

50 Nestor Dr
Meadowbrook QLD 4131

SA / NT

Satellite office servicing all of SA and NT
Adelaide SA 5000

WA

Unit 1, 14 Crocker Dr
Malaga WA 6090